Implantable cardioverter-defibrillators were associated with lower death rates in patients with lower NT-proBNP levels
NT-proBNP and ICD in Nonischemic Systolic Heart Failure: Extended Follow-Up of the DANISH Trial
Randomized trial extended follow-upMixed results
Does baseline NT-proBNP level modify the effect of ICD implantation on mortality?
Who
1116
Patients with nonischemic systolic heart failure · Denmark
Compared
NT-proBNP below median with ICD: HR: 0.75 (95% CI: 0.55-1.03)
NT-proBNP above median with ICD: HR: 0.95 (95% CI: 0.74-1.21)
Main outcome
Death from any cause
Result: HR: 0.75 (95% CI: 0.55-1.03) for low NT-proBNP
Bottom line: Lower baseline NT-proBNP levels may identify patients who derive benefit from implantable cardioverter-defibrillator implantation.
JACC Heart Fail · 2022-03-04 · NCT00542945
Same trial (NCT00542945)
Papers we list that report this registered trial, oldest first. Read a secondary analysis alongside the main results.
- Longer follow-up Mixed results
This paper JACC Heart Fail 2022-03 - Longer follow-up Mixed results
Kidney function did not change ICD benefit for sudden death in heart failure J Am Heart Assoc 2024-01 - Longer follow-up Mixed results
Implantable cardioverter-defibrillators did not reduce overall mortality in non-ischaemic heart failure patients Eur J Heart Fail 2024-05
Headline and visual abstract written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Butt JH, Yafasova A, Elming MB, et al. NT-proBNP and ICD in Nonischemic Systolic Heart Failure: Extended Follow-Up of the DANISH Trial. JACC Heart Fail. 2022;10(3):161-171. doi:10.1016/j.jchf.2022.01.003
Spotted a mistake? Suggest a correction