Optimization of dental implant imaging using photon-counting detector computed tomography in oral and maxillofacial surgery: an ex vivo study

Al-Haj Husain A, Demmert TT, Klambauer K, Maintz P, Flohr T, Essig H, et al
Radiology & ImagingBasic science

Study type: Laboratory or animal research: results may not apply to people yet.

Read the full paper free at PubMed Central ↗

Abstract

Objective To determine optimal reconstruction parameters for dental implant imaging using photon-counting detector CT (PCD-CT), including ultra-high-resolution (UHR) images, virtual monoenergetic images (VMI), and iterative metal artifact reduction (iMAR). Materials and methods In this ex vivo study, six pig mandibles were prepared with two titanium-based implants and imaged on a PCD-CT. Scans were reconstructed as UHR images and VMI from 70-190 keV at 10 keV increments with and without iMAR. Two independent readers qualitatively evaluated image quality and artifact severity using five-point visual rating scales (5 = excellent, no or minimal artifacts; and 1 = very poor, non-diagnostic, severe artifacts). Two readers quantified artifact severity, defined as the standard deviations in attenuation in regions of interest adjacent to the implants. Results UHR images without iMAR yielded high image quality (median 5 for both readers) with minor artifact severity (median 4 for both), whereas iMAR reduced image quality (median 3 for both). VMI without iMAR showed decreasing artifacts at higher energy levels. VMI at 120-130 keV achieved optimal image quality (median 5 for both readers at 120 keV, and medians 4 and 5 at 130 keV) with minimal artifacts (median 5 for both), whereas iMAR reduced quality. Quantitative artifact burden decreased with higher energy levels (from 200 HU at 70 keV to 113 HU at 190 keV), and no improvement was observed using iMAR. Conclusions PCD-CT effectively reduces metal-induced artifacts in dental implant imaging, with UHR images and VMI at 120-130 keV providing optimal image quality, while reconstructions with iMAR offered no further benefit. Relevance statement PCD-CT provides excellent dental implant visualization while minimizing the impact of metal artifacts. Key points In this ex vivo study, ultra-high-resolution images and virtual monoenergetic images at 120-130 keV from PCD-CT effectively reduce metal artifacts from dental implants. Effective artifact reduction offers excellent visualization of the bone-implant interface. Iterative metal artifact reduction (iMAR) did not provide additional benefit for visualization of the bone-implant interface.

Topics

Animals; Dental Implants; Artifacts; Swine; Tomography, X-Ray Computed; Mandible; Photons; Image Processing, Computer-Assisted

DOI: 10.1186/s41747-026-00710-5 · PubMed: 41973327

Cite this article

Al-Haj Husain A, Demmert TT, Klambauer K, Maintz P, Flohr T, Essig H. Optimization of dental implant imaging using photon-counting detector computed tomography in oral and maxillofacial surgery: an ex vivo study. Eur Radiol Exp. 2026. doi:10.1186/s41747-026-00710-5

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur Radiol Exp · Nov 13, 2026 · Research · Radiology & Imaging

Photon-counting CT was linked to better image quality for tantalum clips in proton therapy

Eur Radiol Exp · Apr 27, 2026 · Research · Basic science · Radiology & Imaging, Pulmonology

Photon-counting CT for dynamic lung perfusion: validation of a low-dose protocol in a porcine lung transplantation model

Eur Radiol Exp · May 20, 2026 · Research · Radiology & Imaging, Cardiology

Effect of quantum iterative reconstruction on coronary stent assessment in ultra-high resolution photon-counting detector CT: a phantom study

Eur Radiol Exp · May 13, 2026 · Research · Radiology & Imaging, Urology

Dual-conditioned diffusion model with anatomical guidance for geometric distortion correction in prostate MRI

Eur Radiol Exp · Jun 19, 2026 · Research · Radiology & Imaging, Orthopedics & Sports Medicine

Photon-counting CT: image quality evaluation in patients with tibial plateau fracture treated with metallic osteosynthesis material