Visual abstractsVisuals
ResearchEuropean Radiology Experimental · May 20, 2026

Effect of quantum iterative reconstruction on coronary stent assessment in ultra-high resolution photon-counting detector CT: a phantom study

Scheuer ST, Kusk MW, Sæderup H, Grumsen L, Diaconu A, Arnoldson HP, et al
Radiology & ImagingCardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective This study seeks to assess the impact of quantum iterative reconstruction (QIR) on objective measures of contrast-to-noise ratio (CNR), lumen diameter, and stent strut thickness using photon-counting detector computed tomography (PCD-CT) in ultra-high resolution mode (UHR) in a coronary phantom. Materials and methods A three-dimensional printed phantom (four parallel vessels; 3 vessels with varying 3.5-mm stent types) was applied. Demineralized water, mixed with iodinated contrast, was circulated through the phantom by a dynamic pump. Images were acquired on a commercially available PCD-CT system using retrospective helical acquisition in UHR mode at both 120 and 140 kVp. Images were reconstructed at four QIR-levels (1‒4) using three sharp vascular kernels (Bv56u, Bv68u, and Bv76u). Quantitative evaluations of lumen diameter (mm) and stent strut thickness (mm) were assessed by attenuation profiles using an in-house MATLAB script. Results Increasing QIR level from 1 to 4 improved CNR from 1.5 (95% confidence interval [CI] 1.31‒1.70) (QIR-level 1) to 3.33 (95% CI: 2.89‒3.77) (QIR-level 4), p < 0.001. There was no change (QIR-level 1 to 4) in lumen diameter, range 2.95 mm (95% CI: 2.89‒3.02) to 2.97 mm (95% CI: 2.91‒3.03) (p = 0.890) or strut thickness, range 0.62 mm (95% CI: 0.59‒0.65) to 0.61 mm (95% CI: 0.58‒0.65 ((p = 0.870), regardless of contrast concentration or reconstruction kernel. Conclusion Increasing QIR-level in UHR mode PCD-CT in a stented coronary phantom improved CNR without affecting objective measures of lumen diameter or stent strut thickness under controlled phantom conditions. Relevance statement There has been debate regarding the negative impact of iterative reconstruction on spatial resolution, potentially increasing blooming artifacts caused by coronary stents, which is of special concern when imaging small stent lumens. Currently, no studies have assessed the effect of QIR on the objective assessment of coronary stents. Key points Some earlier implementations of iterative reconstruction negatively impacted spatial resolution, raising concerns for small-vessel and stent imaging. No prior studies examined the effect of QIR on coronary stent assessment. The effect of QIR was evaluated at four levels (1‒4) in a stented coronary phantom. Increasing QIR to the highest level significantly improved luminal CNR. Objective measures of stent dimensions remained unchanged across all QIR levels.

Topics

Stents; Phantoms, Imaging; Coronary Vessels; Tomography, X-Ray Computed; Humans; Photons; Signal-To-Noise Ratio; Radiographic Image Interpretation, Computer-Assisted; Image Processing, Computer-Assisted

DOI: 10.1186/s41747-026-00739-6 · PubMed: 42159889

Cite this article

Scheuer ST, Kusk MW, Sæderup H, Grumsen L, Diaconu A, Arnoldson HP. Effect of quantum iterative reconstruction on coronary stent assessment in ultra-high resolution photon-counting detector CT: a phantom study. Eur Radiol Exp. 2026. doi:10.1186/s41747-026-00739-6

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur Radiol Exp · May 7, 2026 · Research · Radiology & Imaging, Digital Health & AI

Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study

Eur Radiol Exp · Jun 8, 2026 · Research · Radiology & Imaging, Digital Health & AI

The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study

Eur Radiol Exp · Jan 26, 2026 · Research · Radiology & Imaging, Digital Health & AI

Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings

Eur Radiol · Feb 19, 2026 · Research · Radiology & Imaging, Cardiology

Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT-Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions

Eur Radiol Exp · Dec 2, 2025 · Research · Radiology & Imaging, Cardiology

Spectral ultrahigh-resolution photon-counting CT for coronary stent imaging: evaluation in a dynamic phantom