ResearchEuropean Radiology · Feb 19, 2026

Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT-Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions

Fink N, Koetzier LR, Zsarnoczay E, Vecsey-Nagy M, Kravchenko D, Hagar MT, et al
Radiology & ImagingCardiologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Objectives Coronary artery calcium (CAC) scoring is a well-established method for cardiovascular risk assessment but has limited reproducibility. For energy-integrating detector (EID)-CT, a new, multivendor validated protocol has been proposed. This study aimed to investigate the variability of photon-counting detector (PCD)-CT-based CAC scoring and propose a new protocol with decreased variability. Materials and methods A chest phantom containing nine calcifications was scanned on a PCD-CT using various settings: tube voltages (90 kVp, 120 kVp), tube currents (100% to 25% dose), slice thickness (3 mm, 1 mm), quantum iterative reconstruction (IR, 1-4). To evaluate interscan variability, phantoms were scanned five times per protocol with slight translational (5 mm) and rotational (2°) movements. The standard PCD-CT protocol used 120 kVp, 100% dose, 3 mm slices. CAC scores, image noise, and calcification detectability were assessed. Results were compared to the standard PCD-CT, and standard and proposed EID-CT protocols. Results Compared to the standard PCD-CT protocol, score variability decreased by 37% using a thin-sliced protocol at 120 kVp, 25% dose reduction and IR2. Compared to the proposed EID-CT protocol, variability was 66% lower. The optimized PCD-CT protocol met noise targets, eliminating the risk of false-positives. While 6.0 ± 0.0 and 7.0 ± 0.4 calcifications were detected using the PCD-CT standard and the proposed EID-CT protocol, respectively, 7.1 ± 0.7 calcifications were detected with the optimized PCD-CT protocol. Volume and mass scores were closer to physical reference. Conclusions A thin-slice, 25%-dose-reduced PCD-CT protocol at 120 kVp improves CAC score reproducibility and outperforms the proposed EID-CT protocol, possibly offering more reproducible CAC quantification at lower radiation doses. Key points Question Coronary artery calcium scoring is used for cardiovascular risk stratification. However, the current standard method lacks score reproducibility. Findings A thin-slice, 25%-dose-reduced photon-counting detector CT protocol at 120 kVp significantly reduces score variability compared to previous protocols, including the proposed energy-integrating detector CT protocol. Clinical relevance Improved reproducibility of coronary artery calcium scoring may enable more consistent cardiovascular risk prediction and provide a robust technical basis for further in vivo studies.

Subject terms

Phantoms, Imaging; Reproducibility of Results; Coronary Artery Disease; Humans; Photons; Radiation Dosage; Tomography, X-Ray Computed; Radiographic Image Interpretation, Computer-Assisted; Coronary Vessels; Calcinosis

DOI: 10.1007/s00330-026-12355-4 · PubMed: 41711882

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Fink N, Koetzier LR, Zsarnoczay E, et al. Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT-Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions. Eur Radiol. 2026;36(7):5546-5556. doi:10.1007/s00330-026-12355-4

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Radiology & Imaging studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Research · Eur Radiol · Feb 19, 2026 · Radiology & Imaging, Cardiology

Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT Part II: Impact of virtual monoenergetic image reconstructions with adjusted calcium scoring thresholds

Research · Eur Radiol Exp · May 20, 2026 · Radiology & Imaging, Cardiology

Effect of quantum iterative reconstruction on coronary stent assessment in ultra-high resolution photon-counting detector CT: a phantom study

Research · Eur Radiol · Apr 29, 2026 · Radiology & Imaging, Pulmonology

Comparing the detectability of pulmonary nodules on two ultra-high resolution CT scanners: a preliminary phantom study

Research · Eur Radiol Exp · May 7, 2026 · Radiology & Imaging, Digital Health & AI

Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study

Research · Eur Radiol Exp · Jul 1, 2026 · Radiology & Imaging, Gastroenterology & Hepatology

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction