ResearchEuropean Radiology Experimental · Jul 1, 2026

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction

Gulizia M, Dromain C, Haefliger L, Chettab H, Chevallier C, Viry A
Radiology & ImagingGastroenterology & HepatologyDigital Health & AIAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective To determine the optimal low-keV level using deep learning image reconstruction (DLIR) that maximizes lesion detectability, and to assess the potential for iodinated contrast media (ICM) reduction based on detectability improvements across varying patient body habitus. Materials and methods An abdominal phantom was scanned using a standard thoraco-abdomino-pelvic dual-energy computed tomography (DECT) protocol during the portal venous phase, with three rings inserted simulating different body habitus. Virtual monoenergetic images (VMI) were reconstructed from 40 to 70 keV in 10 keV increments using adaptive statistical iterative reconstruction-V (ASIR-V) 50% and high-strength DLIR (DLIR-H). Contrast enhancement was quantified, spatial resolution was evaluated with the task-based transfer function, and noise characteristics were analyzed using the noise power spectrum. Low-contrast lesion detectability (5-10 mm) was assessed using an anthropomorphic model observer. Results Compared to ASIR-V, DLIR-H provided equivalent contrast, reduced image noise, and improved spatial resolution. All lesion sizes with DLIR-H were technically detectable under all conditions. The reconstruction at 40 keV demonstrated the highest detectability of hypovascular lesions under all conditions. However, a decrease in detectability was observed in the large phantom relative to the small and medium phantoms, resulting in a reduced theoretical potential for iodine dose reduction. The theoretical potential for iodine dose reduction using 40 keV with DLIR-H is at least 31.3% based on the phantom-based model. Conclusion Under phantom conditions, 40 keV with DLIR-H shows superior detectability of hypovascular lesions under all conditions, suggesting the theoretical possibility of reducing iodine load by up to 31.3%, based on modeled detectability performance. Relevance statement Based on a phantom-derived model, the combination of 40-keV VMI reconstruction with DLIR-H suggests the potential for more than 30% ICM reduction in oncologic body CT, a finding that warrants confirmation in clinical studies. Key points Based on a phantom-derived model 40 keV VMI with DLIR-H achieved the highest detectability of hypovascular liver lesions. This approach enabled a 31.3% ICM volume reduction. Larger body habitus limits ICM volume reduction optimization margins.

More on this topic

AI in medicine

Subject terms

Phantoms, Imaging; Tomography, X-Ray Computed; Humans; Contrast Media; Deep Learning; Iodine; Radiographic Image Interpretation, Computer-Assisted; Liver Neoplasms; Radiation Dosage; Image Processing, Computer-Assisted; Liver; Radiography, Dual-Energy Scanned Projection

DOI: 10.1186/s41747-026-00759-2 · PubMed: 42384360

Cite this article

Gulizia M, Dromain C, Haefliger L, Chettab H, Chevallier C, Viry A. Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction. Eur Radiol Exp. 2026. doi:10.1186/s41747-026-00759-2

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Research · Eur Radiol Exp · Jun 8, 2026 · Radiology & Imaging, Digital Health & AI

The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study

Research · Eur Radiol Exp · Jan 26, 2026 · Radiology & Imaging, Digital Health & AI

Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings

Research · Eur Radiol Exp · May 7, 2026 · Radiology & Imaging, Digital Health & AI

Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study

Research · Eur Radiol · Apr 29, 2026 · Radiology & Imaging, Pulmonology

Comparing the detectability of pulmonary nodules on two ultra-high resolution CT scanners: a preliminary phantom study

Research · Eur Radiol · Feb 19, 2026 · Radiology & Imaging, Cardiology

Coronary artery calcium scoring: expanding the new standard by photon-counting detector CT-Part I: Impact of tube voltage, tube current, slice thickness, and quantum iterative reconstructions