Visual abstractsVisuals
ResearchEuropean Radiology Experimental · Jan 26, 2026

Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings

Greffier J, Roy C, Dabli D, Beregi JP, Pastor M
Radiology & ImagingDigital Health & AIAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective We compared a super-resolution deep learning image reconstruction (SR-DLR) algorithm with a normal-resolution (NR)-DLR algorithm according to radiation dose for abdominal computed tomography (CT). Materials and methods An image-quality phantom was scanned with an energy-integrating detectors CT unit at three volume CT dose index radiation dose levels (12.7, 5.9, and 3 mGy). Images were reconstructed using a 1,0242 matrix for SR-DLR and a 5122 matrix for NR-DLR, for three DLR levels (level-1, level-2, and level-3). Noise power spectrum (NPS) and task-based transfer function (TTF) for iodine and Solid Water® inserts were computed; TTF values at 50% (f50, mm-1) were used to quantify spatial resolution. The detectability index (d') was computed for two simulated lesions. Results Noise magnitude values were lower with SR-DLR than with NR-DLR for level-2 (-27.6 ± 3.8%) and level-3 (-43.5 ± 1.4%), the opposite for level-1. Average NPS spatial frequency was higher with SR-DLR than with NR-DLR for all radiation dose levels for level-1 (55.9 ± 16.7%) and level-2 (20.1 ± 13.9%) and the opposite for level-3, except at 12.7 mGy. For both inserts, f50 was higher with SR-DLR than with NR-DLR at each radiation dose and DLR level. For simulated lesions and all DLR levels, d' values were higher with SR-DLR than with NR-DLR (level-1, 6.0 ± 2.0%; level-2, 45.7 ± 5.0%; level-3, 75.2 ± 7.3%). Conclusion Compared to NR-DLR, SR-DLR improved spatial resolution and detectability of simulated abdominal lesions; image noise was reduced with SR-DLR only for level-2 and level-3, while image texture was better for level-1 and level-2. Relevance statement Super-resolution DLR with a 1,0242 matrix size improved spatial resolution and detectability of simulated abdominal lesions compared to normal-resolution DLR. Validation in clinical settings is necessary before translation into routine practice. Key points The performance of a new deep learning super-resolution image reconstruction algorithm (SR-DLR) was compared to a normal-resolution (NR)-DLR algorithm using an image-quality phantom for an abdominal energy-integrating detector CT protocol. SR-DLR with a 1,0242 matrix improved spatial resolution and detectability of simulated abdominal lesions compared to NR-DLR with a 5122 matrix. Using SR-DLR, therefore, presents numerous prospects for improving abdominal CT images and a high potential for reducing the radiation doses.

Topics

Deep Learning; Tomography, X-Ray Computed; Phantoms, Imaging; Algorithms; Radiation Dosage; Humans; Image Processing, Computer-Assisted; Signal-To-Noise Ratio; Radiographic Image Interpretation, Computer-Assisted

DOI: 10.1186/s41747-025-00670-2 · PubMed: 41586868

Cite this article

Greffier J, Roy C, Dabli D, Beregi JP, Pastor M. Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings. Eur Radiol Exp. 2026. doi:10.1186/s41747-025-00670-2

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur Radiol Exp · Jun 8, 2026 · Research · Radiology & Imaging, Digital Health & AI

The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study

Eur Radiol Exp · May 7, 2026 · Research · Radiology & Imaging, Digital Health & AI

Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study

Eur Radiol Exp · Jul 1, 2026 · Research · Radiology & Imaging, Gastroenterology & Hepatology

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction

Eur Radiol Exp · Sep 10, 2026 · Research · Radiology & Imaging

Evaluation of deep-learning iterative reconstruction combined with high-frequency kernels in CT: a task-based image quality study

Eur Radiol Exp · May 20, 2026 · Research · Radiology & Imaging, Cardiology

Effect of quantum iterative reconstruction on coronary stent assessment in ultra-high resolution photon-counting detector CT: a phantom study