Evaluation of deep-learning iterative reconstruction combined with high-frequency kernels in CT: a task-based image quality study

Viry A, Monnin P, Pozzessere C, Racine D
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective To evaluate the image quality of a novel deep-learning iterative reconstruction (DLIR) algorithm combined with high-frequency kernels compared with iterative reconstruction (IR) algorithms through the assessment of the detectability of small high-contrast lesions. Materials and methods Three image-quality phantoms were scanned with doses from 0.8 to 15 mGy. Images were reconstructed using ASIR-V0, ASIR-V80, and DLIR (Low, Medium, High), with an edge-enhancing kernel for a chest protocol and a sharp kernel for a spine protocol. A dedicated cubic phantom was used to assess axial, longitudinal resolution, and noise power spectra. Contrast of calcium-based lesions of 3 and 5 mm in diameter was assessed at three concentrations (200, 400, and 800 mg/cc) using two anthropomorphic chest and abdominal phantoms. Detectability was evaluated using a non-prewhitening with eye filter model observer. Results In-plane spatial resolution was stable across DLIR strength levels and slightly better than ASIR-V0, while longitudinal resolution did not depend on algorithms. DLIR markedly reduced image noise, below ASIR-V80 for DLIR-High with both kernels. While IR preserved the contrast of lesions, it decreased with DLIR strength for the small lesion 200 mg/cc-3mm. The highest detectability was achieved with DLIR-High, except for the HA200-3mm below 3 mGy for the chest protocol and 7 mGy for the spine protocol. Conclusion DLIR combined with high-frequency kernels reduced image noise while preserving spatial resolution and FBP-like noise texture, outperforming IR in detectability for most lesion sizes, concentrations, and dose levels. DLIR reduced contrast for small and low-concentration lesions, especially at low doses, which partially counterbalanced its detectability advantage over IR. Key points Question This study evaluates whether deep-learning reconstruction with high-frequency kernels improves the detectability of small high-contrast lesions compared to iterative reconstruction. Findings The new deep-learning reconstruction reduces image noise while preserving fine anatomical detail and improving in-plane spatial resolution. Relevance statement The new deep-learning reconstruction combined with high-frequency kernels improves detection of small lesions in comparison with iterative reconstruction at standard doses, but very small or low-density lesions may appear less visible at lower dose levels.

Topics

Phantoms, Imaging; Tomography, X-Ray Computed; Deep Learning; Algorithms; Humans; Image Processing, Computer-Assisted; Radiographic Image Interpretation, Computer-Assisted

DOI: 10.1186/s41747-026-00801-3 · PubMed: 42720870

Cite this article

Viry A, Monnin P, Pozzessere C, Racine D. Evaluation of deep-learning iterative reconstruction combined with high-frequency kernels in CT: a task-based image quality study. Eur Radiol Exp. 2026. doi:10.1186/s41747-026-00801-3

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur Radiol Exp · Jun 8, 2026 · Research · Radiology & Imaging, Digital Health & AI

The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study

Eur Radiol Exp · Jan 26, 2026 · Research · Radiology & Imaging, Digital Health & AI

Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings

Eur Radiol Exp · Jul 1, 2026 · Research · Radiology & Imaging, Gastroenterology & Hepatology

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction

Eur Radiol Exp · May 7, 2026 · Research · Radiology & Imaging, Digital Health & AI

Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study

Eur Radiol Exp · Sep 30, 2026 · Research · Radiology & Imaging

Quantitative comparison of 68-keV monoenergetic, routine-dose, and low-dose 120-kVp CT for calcium-mimicking inserts in thoracic phantoms: effects of phantom size and reconstruction method