Visual abstractsVisuals
ResearchEuropean Radiology Experimental · Jun 8, 2026

The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study

Su T, Jia Y, Shen Y, Zhang H
Radiology & ImagingDigital Health & AIAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective The aim of this study is to evaluate the performance of a novel deep learning image reconstruction (DLIR) algorithm in noise reduction, contrast-to-noise ratio (CNR), and low iodine concentration detection for ultralow-dose computed tomography (CT) imaging. Methods A nine-hole phantom with iodine concentrations (0-40 mg/mL) was scanned at various tube voltages (60-120 kVp). Images were reconstructed using filtered back projection (FBP), iterative reconstruction (IR), and DLIR at different weight levels (10%-90%). Objective metrics (noise, CNR, CT value accuracy via Bland-Altman analysis) and subjective image quality were assessed. Results At all tube voltages (60-120 kVp), DLIR with medium-to-high weight levels (50%-90%) reduced background noise and increased CNR compared with FBP and IR (p < 0.001). The CNR at a low iodine concentration (1.25 mg/mL) was enhanced, and the DLIR algorithm (weight levels 30%-90%) was able to continuously detect an iodine concentration of 1.25 mg/mL (CNR ≥ 3) at all tube voltages. Under fixed ultralow-dose conditions, DLIR preserved image quality and low-contrast detectability. DLIR (weight levels 90%) reduced background noise by 84.7% compared with FBP and improved CNR (p < 0.001). Bland-Altman analysis confirmed excellent quantitative accuracy for DLIR. The exploratory subjective evaluation was consistent with objective metrics. Conclusion The DLIR algorithm can enhance image quality in low-dose CT imaging and improve the ability to detect low concentrations of iodine. These findings demonstrate that DLIR maintains image quality and CNR at low iodine concentrations in phantom studies. Clinical implications require further validation. Relevance statement This phantom study shows that the deep learning reconstruction algorithm can still maintain the diagnostic image quality and low-contrast detectability even under ultralow-dose CT (94% dose reduction). These findings support further clinical research to optimize the dosage regimens and potentially reduce the use of iodine contrast agents. Key points Under ultralow-dose conditions (60 kV), DLIR preserved image quality metrics and detectability thresholds in a phantom under ultralow-dose conditions. It significantly suppressed image noise and improved the CNR. The algorithm reliably detected low iodine concentrations (1.25 mg/mL) at all dose levels.

Topics

Phantoms, Imaging; Tomography, X-Ray Computed; Deep Learning; Radiation Dosage; Algorithms; Image Processing, Computer-Assisted; Signal-To-Noise Ratio; Humans; Radiographic Image Interpretation, Computer-Assisted; Iodine; Contrast Media

DOI: 10.1186/s41747-026-00751-w · PubMed: 42257775

Cite this article

Su T, Jia Y, Shen Y, Zhang H. The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study. Eur Radiol Exp. 2026. doi:10.1186/s41747-026-00751-w

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur Radiol Exp · Jan 26, 2026 · Research · Radiology & Imaging, Digital Health & AI

Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings

Eur Radiol Exp · May 7, 2026 · Research · Radiology & Imaging, Digital Health & AI

Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study

Eur Radiol Exp · Jul 1, 2026 · Research · Radiology & Imaging, Gastroenterology & Hepatology

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction

Eur Radiol Exp · Sep 10, 2026 · Research · Radiology & Imaging

Evaluation of deep-learning iterative reconstruction combined with high-frequency kernels in CT: a task-based image quality study

Eur Radiol Exp · May 20, 2026 · Research · Radiology & Imaging, Cardiology

Effect of quantum iterative reconstruction on coronary stent assessment in ultra-high resolution photon-counting detector CT: a phantom study