ResearchResuscitation Plus · Sep 28, 2026

Potential harms to rescuers during cardiac arrest response and resuscitation: a scoping review

Lagina AT, Dicker B, Dassanayake V, Dainty K, Morrison LJ, Bray J, et al
Emergency MedicineCritical CareAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Rescuer safety during cardiac arrest response and resuscitation is an important consideration that may influence willingness to intervene. This scoping review identifies potential unintentional harms to rescuers responding to cardiac arrest and performing resuscitation. Methods This scoping review was reported in accordance with PRISMA-ScR guidelines. We searched EMBASE, Medline, and Cochrane from inception to June 16, 2026, including all human studies reporting physical harms during cardiac arrest response or resuscitation (compressions, ventilation, defibrillation). Two investigators screened studies and extracted data. Synthesis was guided by Joanna Briggs Institute methods, with narrative synthesis by harm category. Results Twenty studies were included: sixteen provided direct evidence from cardiac arrest or resuscitation, and four provided indirect evidence from elective cardioversion. Of the direct-evidence studies, nine examined infection transmission during CPR, two evaluated electrical exposure from implantable cardioverter-defibrillators (ICDs) during CPR, two reported physical injuries en route to arrest, and three documented drowning during rescue. Infection transmission rates varied by pathogen but were mitigated by personal protective equipment (PPE). CPR near implantable cardioverter-defibrillators (ICDs) showed potential for higher leakage. In the four indirect-evidence studies, current leakage to rescuers during external shocks delivered for elective cardioversion remained below safe thresholds. One study reported minor injuries from incorrect opening of locked AED cabinets, and another found that injuries en route to patients were rare (<0.7%). Rescue-related drowning fatalities ranged from 0.02 to 0.08 per 100,000 population annually. Conclusions This scoping review suggests harms to rescuers during response or resuscitation are rare. Fatal harms have been reported during water rescue. Minor harms include unsafe AED removal, current leakage during ICD shock delivery, performing CPR without appropriate PPE, and minor injuries en route to a cardiac arrest. Indirect evidence from elective cardioversion suggests external defibrillation poses minimal electrical risk.

More on this topic

Cardiac arrest and resuscitation

DOI: 10.1016/j.resplu.2026.101507 · PubMed: 42935790

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Lagina AT, Dicker B, Dassanayake V, et al. Potential harms to rescuers during cardiac arrest response and resuscitation: a scoping review. Resusc Plus. 2026;32:101507. doi:10.1016/j.resplu.2026.101507

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Emergency Medicine studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

More in Emergency Medicine

Research · BMC Palliat Care · Nov 26, 2026 · Palliative Care, Digital Health & AI

Emergency department entry linked to higher odds of death in palliative care episodes

Research · BMC Palliat Care · Nov 25, 2026 · Palliative Care, Emergency Medicine

Referral to specialized palliative care linked to better symptom control and shorter ED stays

Research · J Med Internet Res · Nov 24, 2026 · Digital Health & AI, Emergency Medicine

Three AI models matched four doctors in emergency triage agreement in a German hospital cohort

Systematic review · J Med Internet Res · Nov 23, 2026 · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

Research · BMJ Med · Nov 18, 2026 · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality