2.2%prophylactic left atrial appendage closure (10/434)
3.1%usual care (14/452)
Main outcome
cardiovascular death, stroke, or systemic embolism at 30 days
Result: hazard ratio 0.29 (95% CI 0.080-1.0) between 7 and 30 days
Bottom line: Prophylactic left atrial appendage closure was safe and did not increase bleeding in patients undergoing bioprosthetic aortic valve replacement.
Limitation: the treatment effect changed direction at approximately 7 days
Clinical question: Does prophylactic left atrial appendage closure reduce stroke risk during bioprosthetic aortic valve replacement?
Why it matters: It was unclear if closing the left atrial appendage during aortic valve replacement reduces risks for patients without a history of atrial fibrillation.
Key points
Researchers studied 904 patients without prior atrial fibrillation undergoing bioprosthetic aortic valve replacement, comparing prophylactic left atrial appendage closure to usual care.
The primary composite endpoint of cardiovascular death, stroke, or systemic embolism occurred in 2.2% of the closure group and 3.1% of the control group.
No closure-related serious complications or differences in bleeding were observed between the two groups during the study period.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.