ResearchResuscitation Plus · Aug 25, 2026

Real-world adoption and use of a ventilation feedback device during out-of-hospital cardiac arrest: a population-based observational study from a French prehospital system

Pretalli JB, Da Cunha M, Hachimi-Idrissi S, Piller LE, Khoury A
Emergency MedicineCardiologyCritical CareAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗
Top Emergency Medicine studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Abstract

Background Ventilation quality during cardiopulmonary resuscitation remains highly variable despite clear guidelines. Ventilation feedback devices have shown substantial improvements in simulated settings, but real-world implementation data remain limited.We aimed to evaluate real-world adoption and use of a ventilation feedback device during out-of-hospital cardiac arrest (OHCA) management in a French prehospital system. Methods We conducted a retrospective, population-based observational study of adult OHCAs jointly managed by firefighters and Mobile Intensive Care Unit teams in the Doubs region. Cases from 2022 (pre-implementation) and 2024 (post-implementation) were analysed. The primary outcome was device utilisation. Secondary outcomes included return of spontaneous circulation, survival, and neurological status, reported descriptively and exploratorily. Results Among 756 patients, 190 (2022) and 166 (2024) met the inclusion criteria. Despite a protocol mandating its systematic use, the device was used in 48/166 (28.9%) cases.Baseline characteristics and resuscitation variables were comparable between groups. Exploratory analyses showed return of spontaneous circulation in 25.0% with device versus 16.1% without (unadjusted odds ratio (OR) = 1.74 confidence interval (CI) 95% [0.77; 3.93]), and survival at day 30 in 10.4% versus 4.2% (unadjusted OR = 2.63 [0.72; 9.53]). Favourable neurological outcome at day 30 was observed in 10.4% versus 3.4% (unadjusted OR = 3.28 [0.84; 12.8]). Given the observational design and limited sample size, these findings should be interpreted as hypothesis-generating. Conclusion This study highlights a discrepancy between protocol and real-world use of a ventilation feedback device during out-of-hospital cardiac arrest. They underscore the need to better understand implementation factors to inform future studies evaluating clinical effectiveness. Future research should incorporate robust implementation strategies and standardised ventilation parameters.

More on this topic

Cardiac arrest and resuscitation

DOI: 10.1016/j.resplu.2026.101465 · PubMed: 42733415

Cite this article

Pretalli JB, Da Cunha M, Hachimi-Idrissi S, Piller LE, Khoury A. Real-world adoption and use of a ventilation feedback device during out-of-hospital cardiac arrest: a population-based observational study from a French prehospital system. Resusc Plus. 2026. doi:10.1016/j.resplu.2026.101465

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Emergency Medicine

Research · BMC Palliat Care · Nov 25, 2026 · Palliative Care, Emergency Medicine

Referral to specialized palliative care linked to better symptom control and shorter ED stays

Research · J Med Internet Res · Nov 24, 2026 · Digital Health & AI, Emergency Medicine

Three AI models matched four doctors in emergency triage agreement in a German hospital cohort

Systematic review · J Med Internet Res · Nov 23, 2026 · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

Research · BMJ Med · Nov 18, 2026 · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality

Research · Am J Emerg Med · Nov 13, 2026 · Emergency Medicine, Hematology

Emergency department blood transfusions were associated with longer stays and higher rates of return