ResearchNature Medicine · Mar 20, 2026

Remote monitoring of heart failure exacerbations using a smartwatch

Gao Y, Moayedi Y, Foroutan F, Verma B, Kim B, Luca E, et al
CardiologyDigital Health & AIAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Heart failure (HF) involves cycles of remission and exacerbation, which are poorly characterized by static disease measures. Consumer wearables have an understudied potential for daily monitoring of HF symptoms. Here we report results from an observational cohort of free-living patients over a median of 94.5 d with HF in the Ted Rogers Understanding Exacerbations of HF (TRUE-HF) study. The study measured the ability of Apple Watch data to predict peak oxygen uptake (pVO2) as measured using in-clinic cardiopulmonary exercise testing (CPET). A deep learning model was trained with data from 154 patients (46 women, 108 men) and validated on a held-out set of 63 patients (24 women, 39 men) for determining wearable-derived daily pVO2, which correlated strongly with CPET-measured pVO2 (Pearson's correlation = 0.85). Each 10% drop in wearable-derived daily pVO2 was associated with a 3.62-fold increased hazard ratio (HR) for unplanned healthcare events (95% confidence interval (CI), 1.37-9.55; P < 0.01), which occurred at a median of 7.4 d after the first 10% drop in wearable-derived pVO2. These findings were externally validated in an independent external cohort from the All of Us Research Program using a crossplatform model that accounted for the reduced-sensor capacities available in this external cohort. Using this reduced-sensor variant of the model, drops in wearable-derived daily pVO2 were associated with unplanned healthcare utilization (HR 1.32, 95% CI 1.03-1.69; P = 0.03), which occurred at a median of 21 d after the first 10% drop in wearable-derived pVO2. These results indicate that wearable-derived daily pVO2 provides earlier and improved risk discrimination compared with existing wearable fitness estimates and established clinical markers and offers a scalable and generalizable approach for longitudinal HF research and monitoring.

More on this topic

Heart failure

Subject terms

Humans; Heart Failure; Male; Female; Wearable Electronic Devices; Aged; Exercise Test; Remote Patient Monitoring; Oxygen Consumption; Middle Aged; Digital Health

DOI: 10.1038/s41591-026-04247-3 · PubMed: 41862772

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Gao Y, Moayedi Y, Foroutan F, et al. Remote monitoring of heart failure exacerbations using a smartwatch. Nat Med. 2026;32(3):924-933. doi:10.1038/s41591-026-04247-3

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Review · Eur Heart J · Mar 25, 2026 · Cardiology, Digital Health & AI

Wearable devices and cardiovascular health: revolutionizing remote monitoring and disease prevention

Research · J Med Internet Res · Oct 30, 2026 · Digital Health & AI, Neurology

Wearable devices acceptable for monitoring Parkinson disease mobility remotely

Randomized trial n = 51 · Eur J Heart Fail · Feb 1, 2021 · Cardiology

Inorganic nitrite improves oxygen transport in the muscles and lungs during exercise in heart failure

Randomized trial n = 20 · JACC Heart Fail · Mar 29, 2025 · Cardiology

Exogenous ketone supplementation did not improve exercise capacity in patients with heart failure

Randomized trial n = 55 · JACC Heart Fail · Jun 26, 2025 · Cardiology, Pulmonology

Dynamic hyperinflation was associated with higher pulmonary capillary wedge pressure during exercise in heart failure patients