Automated insulin delivery reduced time below glucose range compared to sensor and pump therapy
Safety and Efficacy of Sustained Automated Insulin Delivery Compared With Sensor and Pump Therapy in Adults With Type 1 Diabetes at High Risk for Hypoglycemia: A Randomized Controlled Trial
Clinical question: Is automated insulin delivery safer and more effective than sensor and pump therapy?
- The study randomized 72 adults with type 1 diabetes at high risk for hypoglycemia to receive either automated insulin delivery or sensor and pump therapy for 12 weeks.
- Automated insulin delivery resulted in a -3.7% change in time below 70 mg/dL, an 8.6% increase in time between 70-180 mg/dL, and a -5.3% decrease in time above 180 mg/dL.
- Two severe hypoglycemic episodes occurred during the period when participants used automated insulin delivery.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Renard E, Joubert M, Villard O, et al. Safety and Efficacy of Sustained Automated Insulin Delivery Compared With Sensor and Pump Therapy in Adults With Type 1 Diabetes at High Risk for Hypoglycemia: A Randomized Controlled Trial. Diabetes Care. 2023;46(12):2180-2187. doi:10.2337/dc23-0685
Spotted a mistake? Suggest a correction