Randomized trialBMC Medicine · Dec 24, 2025

Three months of dual antiplatelet therapy was non-inferior to 12 months after stent implantation

Three vs 12-month DAPT after implantation of biodegradable-polymer sirolimus-eluting coronary stent: a randomised clinical trial

Yang H, Zhang F, Zhang X, Wu Y, Zhong Z, Wang J, et al
CardiologyAdult
Randomised, open-label, non-inferiority trialBenefit found
Is 3-month dual antiplatelet therapy as safe as 12-month therapy after Firehawk stent implantation?
Who
2445
Patients undergoing percutaneous coronary intervention with Firehawk stents · 36 centres in China
Compared
10.1%3-month dual antiplatelet therapy
10.9%12-month dual antiplatelet therapy
Main outcome
Composite of all-cause death, myocardial infarction, cerebrovascular accident, and major bleeding
Result: absolute rate difference, -0.76% (upper limit of 1-sided 97.5% CI, 1.70%)
Bottom line: Three-month dual antiplatelet therapy is non-inferior to 12-month therapy for the primary composite endpoint.
BMC Med · 2025-12-24 · Save PNG

Clinical question: Is 3-month dual antiplatelet therapy as safe as 12-month therapy after Firehawk stent implantation?

Why it matters: Doctors seek to reduce bleeding risks by potentially shortening the duration of dual antiplatelet therapy after drug-eluting stent implantation.

Key points

Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.

Was this summary helpful?

Read the full paper free at PubMed Central ↗⬇ Slide🖨 Handout

Subject terms

Humans; Male; Female; Drug-Eluting Stents; Middle Aged; Aged; Platelet Aggregation Inhibitors; Percutaneous Coronary Intervention; Sirolimus; Absorbable Implants; Hemorrhage; Polymers

DOI: 10.1186/s12916-025-04515-y · PubMed: 41444578 · Registered: NCT03008083

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Yang H, Zhang F, Zhang X, et al. Three vs 12-month DAPT after implantation of biodegradable-polymer sirolimus-eluting coronary stent: a randomised clinical trial. BMC Med. 2025;23(1):690. doi:10.1186/s12916-025-04515-y

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Randomized trial n = 1,948 · Circulation · Aug 25, 2023 · Cardiology, Hematology

Biodegradable-polymer stents were noninferior to durable-polymer stents in patients at high bleeding risk

Secondary analysis of a trial n = 2,013 · J Am Heart Assoc · Feb 20, 2026 · Cardiology

Orsiro stent had better outcomes than Coroflex in complex heart procedures

Randomized trial n = 1,720 · JACC · Oct 30, 2024 · Cardiology

Low-dose biodegradable polymer stent was noninferior to second-generation stents for coronary artery disease

Randomized trial n = 4,579 · JACC · Aug 18, 2022 · Cardiology

Medication nonadherence did not change outcomes in a trial of short versus long antiplatelet therapy

Randomized trial n = 1,387 · JAMA Netw Open · Mar 4, 2024 · Cardiology

Shorter dual antiplatelet therapy matched longer regimen for safety after stent placement