Transferability and Between Laboratory Imprecision of an LC-MS/MS-Based Reference Measurement Procedure for Apolipoproteins
Abstract
Background
Apolipoprotein standardization in multiple calibration laboratories requires equivalent results to value assign matrix-based reference and external quality assurance materials. A multiplexed LC-MS/MS-based reference measurement procedure (RMP) has been developed for serum apolipoproteins apo(a), apoA-I, apoB, apoC-I, apoC-II, apoC-III, and apoE. This study evaluates the transferability of the RMP between 3 calibration labs and determines the between-laboratory imprecision. Methods
Six periodic ring trial surveys were held. The study protocol, calibrators, internal standards, quality controls (QCs), and clinical samples (CSs) were shared among the laboratories. Intra-laboratory imprecision and inter-peptide comparisons evaluated intra-laboratory performance, while inter-laboratory imprecision evaluated equivalence between the calibration labs. Precision of the common bilevel QC monitored the level of harmonization over time. Results
Intra-laboratory imprecision fulfilled predefined analytical performance, defined as repeatability <50% of the maximum allowable uncertainty (MAU) at minimal criteria. Median interlaboratory variation (CVbl) was 3.71%, 3.33%, 7.38%, 6.74%, 3.88%, and 3.90% for apoA-I, apoB, apoC-I, apoC-II, apoC-III, and apoE, respectively. For apo(a), CVbl was concentration (x) dependent following 206.32×x-0.899%. In QC samples, the average imprecision for all apolipoproteins decreased from 6.0% and 18.1% for QC1 and QC2, to 5.2% and 9.5%, indicating improvement of analytical performance of the network over time. Conclusions
This study shows the feasibility of transferring the multiplex apo LC-MS/MS-based RMP between laboratories. Predefined performance specifications were fulfilled for all seven apolipoproteins. Ongoing round-robin studies will ensure stable performance of the calibration labs required to accomplish an accurate value-base for apolipoprotein certification of commercial reagents.
Topics
Cite this article
Ruhaak LR, Kuklenyik Z, Dittrich J, Dantuma E, Romijn F, Diederiks NM. Transferability and Between Laboratory Imprecision of an LC-MS/MS-Based Reference Measurement Procedure for Apolipoproteins. Clin Chem. 2026. doi:10.1093/clinchem/hvag020
Spotted a mistake? Suggest a correction