ResearchJournal of the American Heart Association · Jan 22, 2026

Comparing Clinical Outcomes of Patients With a Small Versus Large Annulus After Newer-Generation Balloon-Expandable Transcatheter Aortic Valve Replacement

Suruga K, Patel V, Nagasaka T, Guo Y, Shitan H, Ng D, et al
CardiologyCardiothoracic & Vascular SurgeryPhysical Medicine & RehabilitationAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Limited data are available comparing clinical outcomes between patients with small and large annuli following transcatheter aortic valve replacement using balloon-expandable valves. This study sought to investigate 5-year clinical outcomes in patients with severe aortic stenosis with a small annulus compared with those with a large annulus following transcatheter aortic valve replacement with newer-generation balloon-expandable valves. Methods A total of 3182 patients with aortic stenosis treated with balloon-expandable valves were divided into small-annulus (≤430 mm2) and large-annulus (>430 mm2) groups. A 1:1 propensity-matched analysis was performed to adjust baseline differences. The primary end point was all-cause death at 5-year follow-up. Secondary end points included heart failure hospitalization, bioprosthetic valve failure, and aortic valve reintervention. Results Among 533 matched pairs, compared with the large-annulus group, the small-annulus group had higher rates of aortic valve mean gradients ≥20 mm Hg (14.1% versus 2.9%; P<0.001) and severe prosthesis-patient mismatch (9.8% versus 5.2%; P=0.019). At 5 years, there were no significant differences in all-cause death (hazard ratio, 0.75 [95% CI, 0.52-1.09]; P=0.13). The incidence of heart failure rehospitalization, bioprosthetic valve failure, and aortic valve reintervention were similar between groups. Both groups achieved similar sustained improvements in New York Heart Association functional class and Kansas City Cardiomyopathy Questionnaire-Overall Summary scores. Conclusions Despite higher transvalvular gradients and a greater rate of severe prosthesis-patient mismatch, 5-year clinical outcomes in patients with a small annulus were comparable to those with a large annulus following transcatheter aortic valve replacement using newer-generation balloon-expandable valves.

Subject terms

Humans; Aortic Valve Stenosis; Heart Valve Prosthesis; Transcatheter Aortic Valve Replacement; Prosthesis Design; Female; Male; Aortic Valve; Aged, 80 and over; Treatment Outcome; Bioprosthesis; Prosthesis Failure

DOI: 10.1161/JAHA.125.043880 · PubMed: 41568567

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Suruga K, Patel V, Nagasaka T, et al. Comparing Clinical Outcomes of Patients With a Small Versus Large Annulus After Newer-Generation Balloon-Expandable Transcatheter Aortic Valve Replacement. J Am Heart Assoc. 2026. doi:10.1161/JAHA.125.043880

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Systematic review · Ann Thorac Surg · Jan 27, 2025 · Cardiothoracic & Vascular Surgery, Cardiology

Bioprosthetic valve fracture may improve hemodynamics during transcatheter aortic valve-in-valve replacement

Secondary analysis of a trial · JAMA Cardiol · Jun 24, 2026 · Cardiology, Cardiothoracic & Vascular Surgery

TAVR and surgery showed similar valve durability at seven years in low-risk patients

Randomized trial · JACC · May 18, 2022 · Cardiology

Self-expanding valves showed better blood flow measurements than balloon-expandable valves in small surgical valve replacements

Randomized trial · Eur J Cardiothorac Surg · Jun 13, 2021 · Cardiothoracic & Vascular Surgery, Cardiology

Sutureless aortic valve implantation was associated with higher rates of transient platelet reduction

Randomized trial · Eur J Cardiothorac Surg · Mar 16, 2022 · Cardiothoracic & Vascular Surgery, Cardiology

Sutureless aortic valves were associated with higher permanent pacemaker implantation rates than stented valves