Visual abstractsVisuals
ResearchBritish Journal of Anaesthesia · Aug 29, 2026

Computed tomography of three smaller-sized supraglottic airway device prototypes in stillborn low-birth-weight neonates

Dempsey T, Brismar TB, Svensson-Marcial A, Blennow M, Alfvén T, Pejovic N, et al
AnesthesiologyPediatric
Read the full paper free at the publisher ↗

Abstract

Background Supraglottic airway devices are used for neonatal resuscitation and surfactant administration, but options for low-birth-weight neonates remain sparse. This study evaluated three smaller-sized supraglottic airway device prototypes in low-birth-weight stillborn neonates. Methods The smallest commercially available i-gel® (Intersurgical Ltd) (size 1.0) and three smaller-sized prototypes, Neo i-gel® sizes 0.65, 0.75, and 0.85, were evaluated. Anatomical positioning of the devices in stillborn neonates weighing more than 500 g was assessed using photon-counting CT. Measurements included device placement relative to perilaryngeal landmarks and impact on adjacent structures. Results Six stillborn neonates were included, comprising two neonates per weight category: (I) 500-750 g, (II) 1250-1750 g, and (III) 1750-2250 g. In weight category I, sizes 0.85 and 1.0 were too large to be inserted; for sizes 0.65 and 0.75, the results were inconclusive because of a fitting discrepancy within the group. In weight categories II and III, the anatomical fit was suitable for sizes 0.75 and 0.85. A weak trend showed that the effect on adjacent structures increased with larger device size. Conclusions The smallest commercially available i-gel®, size 1.0, was markedly too large for all neonates weighing up to 1750 g and too large to be considered anatomically suitable for neonates weighing up to 2250 g. Our findings underscore the necessity of smaller supraglottic airway devices, but further functional validation is necessary before making any definitive weight-based recommendations.

Topics

Humans; Infant, Newborn; Laryngeal Masks; Tomography, X-Ray Computed; Equipment Design; Infant, Low Birth Weight; Female; Male; Intubation, Intratracheal

DOI: 10.1016/j.bja.2026.07.011 · PubMed: 42665488

Cite this article

Dempsey T, Brismar TB, Svensson-Marcial A, Blennow M, Alfvén T, Pejovic N. Computed tomography of three smaller-sized supraglottic airway device prototypes in stillborn low-birth-weight neonates. Br J Anaesth. 2026. doi:10.1016/j.bja.2026.07.011

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Crit Care · Dec 5, 2025 · Randomized trial · Critical Care

Influence of different airway devices on intra-arrest ventilation during bag-valve-device ventilation - a prospective randomized controlled cadaver study

Ann Thorac Surg · Nov 25, 2025 · Randomized trial · Cardiothoracic & Vascular Surgery

Randomized Trial of High-Flow Nasal Cannula vs Double-Lumen Endotracheal Tube or Laryngeal Mask for Thoracoscopic Surgery

BMJ · Nov 4, 2026 · Randomized trial · Pediatric · Pediatrics, Pulmonology Visual abstract

Laryngeal mask airway reduced respiratory adverse events in children undergoing adenotonsillectomy

Eur Radiol · Apr 29, 2026 · Research · Radiology & Imaging

Comparing the detectability of pulmonary nodules on two ultra-high resolution CT scanners: a preliminary phantom study

Am J Public Health · Jun 24, 2026 · Research · Public & Global Health

Aligning Health and Social Systems to Improve Maternal Behaviors and Birth Outcomes Among Clients Engaged in Evidence-Based Home Visiting