High-flow nasal cannula therapy failed to show noninferiority to continuous positive airway pressure in children
Effect of High-Flow Nasal Cannula Therapy vs Continuous Positive Airway Pressure Following Extubation on Liberation From Respiratory Support in Critically Ill Children: A Randomized Clinical Trial
Clinical question: Is high-flow nasal cannula noninferior to continuous positive airway pressure for liberation from respiratory support?
Why it matters: The optimal first-line mode of noninvasive respiratory support, such as high-flow nasal cannula or continuous positive airway pressure, following extubation in critically ill children is not known.
- Researchers studied 600 children aged 0 to 15 years randomized to receive either high-flow nasal cannula or continuous positive airway pressure after being taken off a breathing tube.
- High-flow nasal cannula failed to meet noninferiority for time to liberation from respiratory support, with a median of 50.5 hours compared to 42.9 hours for continuous positive airway pressure.
- Mortality at day 180 was significantly higher for the high-flow nasal cannula group at 5.6% compared to 2.4% for the continuous positive airway pressure group.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Cite this article
Ramnarayan P, Richards-Belle A, Drikite L, Saull M, Orzechowska I, Darnell R. Effect of High-Flow Nasal Cannula Therapy vs Continuous Positive Airway Pressure Following Extubation on Liberation From Respiratory Support in Critically Ill Children: A Randomized Clinical Trial. JAMA. 2022. doi:10.1001/jama.2022.3367
Spotted a mistake? Suggest a correction