Randomized trialEuropean Radiology · Apr 18, 2023

Halved contrast medium dose in lower limb dual-energy computed tomography angiography-a randomized controlled trial

Kristiansen CH, Thomas O, Tran TT, Roy S, Hykkerud DL, Sanderud A, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Objectives To compare vascular attenuation (VA) of an experimental half iodine-load dual-layer spectral detector CT (SDCT) lower limb computed tomography angiography (CTA) with control (standard iodine-load conventional 120-kilovolt peak (kVp) CTA). Methods Ethical approval and consent were obtained. In this parallel RCT, CTA examinations were randomized into experimental or control. Patients received 0.7 vs 1.4 mL/kg of iohexol 350 mgI/mL in the experimental- vs the control group. Two experimental virtual monoenergetic image (VMI) series at 40 and 50 kiloelectron volts (keV) were reconstructed. Primary outcome VA. Secondary outcomes image noise (noise), contrast- and signal-to-noise ratio (CNR and SNR), and subjective examination quality (SEQ). Results A total of 106 vs 109 were randomized and 103 vs 108 were analyzed in the experimental vs, control groups, respectively. VA was higher on experimental 40 keV VMI than on control (p < 0.0001), but lower on 50 keV VMI (p < 0.022). Noise was higher on experimental 40 keV VMI than on control (p = 0.00022), but lower on 50 keV VMI (p = 0.0033). CNR and SNR were higher than the control on experimental 40 keV VMI (both p < 0.0001) and 50 keV (p = 0.0058 and p = 0.0023, respectively). SEQ was better on both VMIs in the experimental group than in the control (both p < 0.0001). Conclusions Half iodine-load SDCT lower limb CTA at 40 keV achieved higher VA than the control. CNR, SNR, noise, and SEQ were higher at 40 keV, while 50 keV showed lower noise. Clinical relevance statement Spectral detector CT with low-energy virtual monoenergetic imaging performed halved iodine contrast medium (CM) lower limb CT-angiography with sustained objective and subjective quality. This facilitates CM reduction, improvement of low CM-dosage examinations, and examination of patients with more severe kidney impairment. Trial registration Retrospectively registered 5 August 2022 at clinicaltrials.gov NCT05488899. Key points • Contrast medium dosage may be halved in lower limb dual-energy CT angiography with virtual monoenergetic images at 40 keV, which may reduce contrast medium consumption in the face of a global shortage. • Experimental half-iodine-load dual-energy CT angiography at 40 keV showed higher vascular attenuation, contrast-to-noise ratio, signal-to-noise ratio, and subjective examination quality than standard iodine-load conventional. • Half-iodine dual-energy CT angiography protocols may allow us to reduce the risk of PC-AKI, examine patients with more severe kidney impairment, and provide higher quality examinations or salvage poor examinations when impaired kidney function limits the CM dose.

Topics

Humans; Computed Tomography Angiography; Radiography, Dual-Energy Scanned Projection; Radiographic Image Interpretation, Computer-Assisted; Tomography, X-Ray Computed; Signal-To-Noise Ratio; Renal Insufficiency; Lower Extremity; Iodine; Angiography; Retrospective Studies

DOI: 10.1007/s00330-023-09575-3 · PubMed: 37071166 · Registered: NCT05488899

Cite this article

Kristiansen CH, Thomas O, Tran TT, Roy S, Hykkerud DL, Sanderud A. Halved contrast medium dose in lower limb dual-energy computed tomography angiography-a randomized controlled trial. Eur Radiol. 2023. doi:10.1007/s00330-023-09575-3

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, by email. Free.

Get the weekly digest

Similar articles

Research · Eur Radiol Exp · Jul 1, 2026 · Radiology & Imaging, Gastroenterology & Hepatology

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction

Research · Eur Radiol Exp · Jun 8, 2026 · Radiology & Imaging, Digital Health & AI

The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study

Research · Eur Radiol · Jun 3, 2026 · Radiology & Imaging

Virtual non-contrast images from dual-layer spectral CT: comparison with true non-contrast across abdominal structures

Research · Eur Radiol Exp · May 7, 2026 · Radiology & Imaging, Digital Health & AI

Reconstruction algorithms and arm positioning effects on abdominal CT image quality and radiation dose: a phantom study

Research · Eur Radiol Exp · May 20, 2026 · Radiology & Imaging, Cardiology

Effect of quantum iterative reconstruction on coronary stent assessment in ultra-high resolution photon-counting detector CT: a phantom study