ResearchEuropean Journal of Heart Failure · Apr 17, 2026

Hemodynamic changes in response to GLP-1 treatment in ICD and CRT patients: insights from HeartLogic sensor data

Fussing FH, Davodian LW, Davodian DW, Johansen ND, Kumarathurai P, Modin D, et al
CardiologyEndocrinology & DiabetesAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Glucagon-like peptide-1 receptor agonist (GLP-1RA) therapy is increasingly used, but the physiological effects in patients with heart failure and reduced ejection fraction (HFrEF) remain uncertain. Continuously collected data from implantable cardiac devices may enable evaluation of drug effects in a real-world setting. Methods In a nationwide Danish retrospective matched cohort study, GLP-1RA initiators with implantable cardiac devices were matched 1:5 to unexposed device recipients by sex and age. Sensor data were assessed from 30 days before to 30 days after initiation. Primary outcomes were changes in heart rate and thoracic impedance. Analyses were adjusted for baseline sensor value, BMI category, hypertension, and type 2 diabetes. Prespecified subgroup analyses were performed in patients with HFrEF. Results In 666 patients (111 GLP-1RA initiators, 555 matched controls), semaglutide was used in 95% of initiators. Compared with controls, GLP-1RA initiation was associated with higher night heart rate (adjusted difference 2.12 bpm; 95% CI, 1.38-2.87), higher daily heart rate (1.46 bpm; 95% CI, 0.65-2.06), and higher thoracic impedance (0.66 Ω; 95% CI, 0.17-1.15) (all P < .01). S1 amplitude decreased (-0.09 mG; 95% CI, -0.14 to -0.04; P < .01). Heart rate increases followed a stepwise pattern across semaglutide dose levels, with an average increase of 2.5 bpm per dose escalation. Findings were directionally consistent in patients with HFrEF (GLP-1RA n = 80), with no evidence of effect modification. Conclusion GLP-1RA initiation was associated with measurable changes in device-derived physiology. Larger studies are needed to evaluate clinical implications, including in HFrEF.

More on this topic

Heart failureGLP-1 receptor agonists (semaglutide, tirzepatide)

Subject terms

Humans; Female; Male; Heart Failure; Retrospective Studies; Semaglutide; Defibrillators, Implantable; Heart Rate; Stroke Volume; Aged; Glucagon-Like Peptide-1 Receptor Agonists; Denmark

DOI: 10.1093/ejhf/xuag114 · PubMed: 41990363

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Fussing FH, Davodian LW, Davodian DW, et al. Hemodynamic changes in response to GLP-1 treatment in ICD and CRT patients: insights from HeartLogic sensor data. Eur J Heart Fail. 2026. doi:10.1093/ejhf/xuag114

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Randomized trial · Eur J Heart Fail · May 11, 2024 · Cardiology

Implantable cardioverter-defibrillators did not reduce overall mortality in non-ischaemic heart failure patients

Randomized trial · JACC Heart Fail · Mar 4, 2022 · Cardiology

Implantable cardioverter-defibrillators were associated with lower death rates in patients with lower NT-proBNP levels

Randomized trial · J Am Heart Assoc · Jan 31, 2024 · Cardiology, Nephrology

Kidney function did not change ICD benefit for sudden death in heart failure

Guideline · Eur J Heart Fail · Apr 9, 2025 · Cardiology

Expert consensus addresses delays in cardiac rhythm device use for heart failure patients

Randomized trial · Eur Heart J · May 11, 2024 · Cardiology, Pulmonology

Pulmonary artery pressure monitoring benefits remained consistent across various patient subgroups in heart failure