ResearchEuropean Radiology · May 14, 2026

TOPOS: target organ prediction on scout views for automated CT scan planning

Ziegelmayer S, Lemke T, Graf M, Kim SH, Lemke L, Mertens CJ, et al
Radiology & ImagingAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Overscanning is a common issue in CT planning, leading to unnecessary radiation exposure. Purpose To develop a deep learning model to segment anatomical structures in scout views to optimize scan ranges and reduce radiation. Materials and methods In this single-center retrospective study, 1146 patients undergoing CT between 2022 and 2025 were included. The model was trained on segmentations of 26 target structures in five regions (head, neck, chest, chest-to-pelvis, abdomen-to-pelvis), transferred to scout views and manually corrected. Performance was evaluated using the Dice-Sørensen coefficient and normalized surface distance on an internal test set of 100 patients and 36 external chest CTs. Automated versus manual scan planning was compared in 61 internal (chest, upper abdomen, head) and 14 external (chest) CTs, with z-axis coverage and dose-length product. Results 1146 patients (mean age, 63 ± 17 years; 577 men) were included. For target structures in five regions, mean DSC and NSD were 0.93 and 0.88. External mean DSC across chest targets was 0.851 ± 0.051. Automated planning captured relevant anatomy in 98% of internal and 92.9% of external CTs. Scan length significantly decreased for automated planning in the internal test cohort (chest 50 mm (15%), p < 0.001; upper abdomen 60 mm (25%), p < 0.001; cranial 19 mm (11%), p < 0.001), yielding corresponding DLP reductions of 19%, 25% and 11%, respectively. In the external cohort, scan length decreased by 115 mm (28.7%, p < 0.0001) with a corresponding 28.5% DLP reduction. Conclusion The proposed model enables reliable automated CT scan planning and reduces overscanning and radiation exposure without compromising diagnostic quality. Key points Question Can segmentation of anatomical structures on CT scout views enable automated scan planning to reduce overscanning and unnecessary radiation exposure? Findings A deep learning model segmented planning-relevant anatomy on CT scout views and reduced scan length and dose while preserving anatomical coverage. Clinical relevance Unnecessary radiation from overscanning is a patient safety concern. Automated CT planning with the proposed deep learning model reduces radiation exposure while ensuring full anatomical coverage for the evaluated scan regions.

More on this topic

AI in medicine

Subject terms

Humans; Tomography, X-Ray Computed; Retrospective Studies; Male; Deep Learning; Middle Aged; Female; Radiation Dosage; Aged

DOI: 10.1007/s00330-026-12623-3 · PubMed: 42135580

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Ziegelmayer S, Lemke T, Graf M, et al. TOPOS: target organ prediction on scout views for automated CT scan planning. Eur Radiol. 2026;36(10):7698-7709. doi:10.1007/s00330-026-12623-3

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Radiology & Imaging studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Review · AJR Am J Roentgenol · Feb 4, 2026 · Radiology & Imaging

CT Radiation Dose Reduction With Preserved Diagnostic Performance: How Far Have We Come Over 25 Years?

Meta-analysis · Eur Radiol · Dec 15, 2021 · Radiology & Imaging, Digital Health & AI

Deep learning reconstruction showed similar CT values to other methods

Research · Eur Radiol Exp · Jul 1, 2026 · Radiology & Imaging, Gastroenterology & Hepatology

Optimization of hypovascular liver lesion detectability in dual-energy CT using deep learning image reconstruction: a phantom study for potential iodine dose reduction

Research · Eur Radiol Exp · Jun 8, 2026 · Radiology & Imaging, Digital Health & AI

The impact of a novel deep learning reconstruction algorithm on image quality in ultralow-dose CT: a quantitative phantom study

Research · Eur Radiol Exp · Jan 26, 2026 · Radiology & Imaging, Digital Health & AI

Phantom-based performance comparison of two commercial deep learning CT reconstruction algorithms with super- and normal-resolution settings